Posted in

What is the difference between a bar – type and wound – type Current Transformer?

If you’ve ever walked through a power substation, a manufacturing plant’s control room, or even a residential utility closet hooked up to a large solar array, you’ve probably spotted current transformers (CTs) tucked alongside high-voltage cables or switchgear. As a current transformer supplier, I get asked all the time why there are two main types—bar-type and wound-type—and what sets them apart beyond just their names. A few years back, I had a customer who ordered bar-type CTs for a secondary substation only to realize they needed wound-type for a new expansion that required more flexibility. That mix-up stuck with me, so today I’m breaking down the key differences, use cases, and why choosing the right one matters for your operations. Current Transformer

First, let’s start with the basics: what a current transformer does, in case you’re new to this. CTs step down high alternating current (AC) to a manageable, safe level—usually 5 amps or 1 amp—so you can measure it with standard meters, relay fault circuits, or monitor power usage without risking shock or damaging equipment. Both bar-type and wound-type do this core job, but their construction and design make them suited for totally different scenarios. That’s where the confusion often comes in; people assume all CTs work the same way, but dig into their guts and you’ll see why that’s not the case.

Let’s talk about wound-type CTs first, because they’re the more traditional design. A wound-type CT has a core—usually made of laminated silicon steel to reduce energy loss and overheating—wrapped with multiple turns of copper wire, that’s the “wound” part. That wire is the secondary winding, where the stepped-down current comes out. The primary side, which carries the actual high current, is that copper wire too, built into the CT’s design. So if you open a wound-type CT, you’ll see two sets of windings: the heavy-gauge primary that handles the full line current, and the thinner secondary that connects to your metering gear. This design has been around for decades, and it’s reliable, but it’s also more hands-on when you’re installing it. To wire it up, you have to feed the primary cable or busbar through the CT and connect those heavy primary leads to your circuit. That might sound straightforward, but for high-current applications, those primary leads are bulky—like, inches thick in some cases—so you need to plan for the space to fit them.

Bar-type CTs, on the other hand, flip that construction. Instead of winding multiple turns of wire for the primary, bar-type CTs use a solid bar of copper or aluminum as the primary conductor. That bar is built right into the CT core, so when you install one, you don’t have to run a separate primary cable through it. The bar is the path for the line current, and the secondary winding is wrapped around the core like it is in a wound-type, but it’s sized to match the bar’s current rating. This design is what makes bar-type CTs so much easier to install in tight spaces, and it’s why we’ve seen them take over a lot of new installations in the last 15 years.

Now, let’s get into the practical differences that matter for you, the end user. The first big one is installation time and complexity. If you’re replacing a CT in an existing substation with wound-type, you have to shut down the circuit, disconnect the primary cable, fish it through the CT, and torque those heavy leads securely. That’s hours of work, usually needing two or three technicians to handle the big cables. Bar-type CTs? You just mount them around the existing bar or busbar—no disconnection required (well, not usually; some low-voltage models let you clamp them on for retrofits, though high-voltage ones need proper dead-front installation) and tighten the mounting bolts. We had a customer last year who was retrofitting a 480V assembly line with 10 CTs; swapping out their old wound-type models for bar-type cut their installation time from 8 hours to 90 minutes. That’s a huge win for minimizing downtime, which is make-or-break for manufacturing plants.

Next, current rating flexibility. Wound-type CTs shine when you need to handle very high line currents—like 5,000 amps or more. Because you can add more turns to the primary winding (wait, no, actually, wait: the turns ratio is secondary turns over primary turns, right? So for higher line current, you can either use a thicker primary conductor or more primary turns. Wound-type lets you adjust that by changing how many times you wrap the primary cable through the core. For example, if you have a 2,000 amp line, you can run the primary cable twice through a wound-type CT, making the turns ratio 2:1, so the secondary current is 1,000 amps? No, wait, no—wait, let me get that straight for you, because I don’t want to give bad info. The turns ratio is Np/Ns, where Np is primary turns and Ns is secondary turns. So for a line current of 1,000 amps, if Ns is 200 turns, then Np is 2 turns, so the secondary current is 1,000 * (Np/Ns) = 10 amps, but standard secondary is 5, so adjust accordingly. The point is: with wound-type, you can easily adjust the primary turns to match whatever line current you’re dealing with, which is why they’re the go-to for transmission level substations where line currents are 10,000 amps and up. Bar-type CTs do have current ratings too, but they cap out around 5,000 amps for most standard models. If you need anything above that, wound-type is the only reliable option.

Wait, but bar-type has another advantage here: no primary connection loss. When you wire a wound-type CT, those primary leads create resistance at the connection point, which leads to a little bit of energy loss, and over time, that connection can corrode, leading to inaccurate current readings. Bar-type CTs have the primary conductor built right in, so there’s no external connection to corrode or add resistance. That means more consistent, accurate readings over the life of the CT, which is huge for billing, load monitoring, and fault detection. A bad connection on a wound-type CT can throw off your readings by 2-3%, which might not sound like a lot, but for a facility that uses $100,000 worth of power a month, that’s $2,000 or more in overbilling or incorrect load data. I’ve seen that happen more than once, so that’s a big selling point for bar-type for commercial and industrial facilities with mid-range current needs.

Another difference is size and weight. Wound-type CTs for high current are massive—think 50+ pounds, with a footprint that takes up 2 square feet of space. Bar-type CTs, for the same current rating, are half that size and weight. That makes them perfect for panel boards, small substation enclosures, or any application where space is at a premium. For example, when we supply CTs for solar inverters, which are usually mounted on rooftops or compact ground mounts, bar-type is the only way to go because you can’t fit a big wound-type CT next to the inverter cabinet.

But bar-type isn’t perfect, and wound-type still has its place. Let’s talk about cost, for one. If you’re buying a low-current CT—say 100 amps or less—wound-type is usually cheaper. The construction is simpler, the parts are easier to source, and the labor to install is lower. Bar-type CTs have the solid bar built in, so they’re a little more expensive for lower current ratings. Also, wound-type is better for custom applications. If you need a CT with a unique turns ratio, or a very specific mounting configuration, wound-type is easier to modify to your needs. Bar-type is pretty standardized, so custom orders take longer, whereas we can usually tweak a wound-type to a customer’s needs in a few days.

There’s also the issue of secondary winding isolation. Wound-type CTs have the secondary winding wrapped around the core, so the distance between the primary and secondary is easily controlled during manufacturing. That makes them better for very high voltage applications, like transmission lines over 100 kV, where insulation between the primary line and the metering circuit is critical for safety. Bar-type CTs also have insulation, but the solid bar can create hot spots or require more careful insulation design at high voltages, so wound-type is still the safer, more reliable choice there.

Let me wrap this up with some real-world scenarios to make it concrete. If you’re a small to mid-sized manufacturing plant with a 480V main service drawing 1,000 amps, you’re probably going to want bar-type CTs. They’re fast to install, fit in your existing panel, have lower installation loss, and are more accurate for your load level. If you’re a utility company building a new substation with a 138 kV line carrying 8,000 amps, you need wound-type CTs. No bar-type can handle that current or that voltage rating, so that’s non-negotiable. If you’re retrofitting an old office building’s power system to add sub-metering, bar-type is the way to go because you don’t have to shut down the whole building to run a primary cable through the CT. If you’re replacing a CT in a 30-year-old transmission substation that’s still using wound-type models, swapping them out for the same type is better for compatibility with your existing relays and metering gear.

As a supplier, I tell every customer the same thing: there’s no “better” CT, only a CT that’s better for your specific job. I’ve seen customers buy bar-type because they thought it was the new, better model, only to find it couldn’t handle their line current. I’ve also seen customers buy cheap wound-type for a 200 amp panel, only to deal with bad connections and inaccurate readings. The key is to know your current rating, your available space, your installation timeline, and your voltage level before you make a call.

If you’re not sure which type is right for your project, I’m here to help. I’ve worked with small businesses, utility companies, and everything in between for over a decade, so I can walk you through the specs, help you calculate your turns ratio, and point you to the CT that will save you time, money, and headaches down the line. Don’t guess—reach out and let’s talk through your needs, no pressure, no sales pitch, just straight talk about what works for your setup.

References

High Voltage Ignition Transformer Kulkarni, S. V., & Khaparde, S. A. (2004). Transformer Engineering: Design and Practice. CRC Press.
Electric Power Research Institute. (2012). Current Transformer Application and Installation Guidelines. EPRI.
IEEE Standard C57.13-2021, Requirements for Instrument Transformers. IEEE.


Shaanxi Magason-Tech Electronics Co., Ltd.
Shaanxi Magason-Tech Electronics Co., Ltd. is one of the most professional current transformer manufacturers and suppliers in China. If you’re going to buy high quality current transformer at competitive price, welcome to get free sample from our factory. Also, customized service is available.
Address: Room #1901, Building No.D, Chanba Financial Center, No.2566 JinQiao 2nd Road, Chanba District, Xi’an City, Shaanxi Province. Zip Code: 710032
E-mail: sales@magason-tech.com
WebSite: https://www.magason-tech.com/